Air Cooled Screw Chiller Maintenance

Two green screw compressors being maintained in an air cooled chiller

Air Cooled Screw Chiller Maintenance

We recently carried out air cooled screw chiller maintenance at a site we look after in the North West. The plant is described such because it uses two Bitzer screw compressors to create a pressure difference in the R134a refrigerant. The plant has been designed to be remotely operated…

Chiller Remote

This is a way of operating the chiller remotely. Instead of the end user having to walk up to the machine each day to check for faults (chiller local) the plant can be remotely operated and monitored.

Run Signal

The run signal to start the chiller is sent by a relay being energised in the BMS panel (Building Management System) in the plant room. When the chiller receives the run signal, it shows the chiller on message.

Fault Feedback

When the chiller develops a fault, the chiller energises a relay, sending a fault feedback signal to the BMS panel. This fault signal causes the run signal to drop out and a new run signal to be sent to the adjacent redundant system.

BMS Panel

The BMS panel runs contactors which bring the water system pumps on, it also receives analogue signals from temperature sensors on the water system. These inputs and outputs are wired into a PCB which converts them into a data signal. This signal is sent down a CAT 5 plug cable to the supervisor in the facilities management room in the building below.

Remote Monitoring During Air Cooled Screw Chiller Maintenance

A supervisor is a computer which has graphic monitoring of the chillers and the air handlers. The supervisor, is connected down a phone line to the BMS company. Often, the chiller is remotely operated and monitored from a laptop used by a BMS engineer working from home.

0161 370 7193

service@maximuschillers.com

Contact Form

Air Cooled Screw Chiller Maintenance Parts

With a comprehensive range of chiller parts available, off the shelf, for air cooled chillers- look no further than Maximus Chillers for all your chiller parts. We can also supply parts mostly same day. A specialist part on this chiller is the electronic expansion valve driver- this regulates the steps in the expansion valve to ensure correct superheat in the shell and tube evaporator. An electronic expansion valve driver is also available to regulate the expansion valve in the refrigerant economiser. This acts to subcool the refrigerant to ensure optimum system efficiency.

Diagnosis During Air Cooled Screw Chiller Maintenance

Should you need chiller diagnosis- one of our trained professionals onsite during the maintenance will identify the issue with his system test equipment.

To read more about air cooled chiller maintenance click the Tag at the top of the page.

Related Blogs:
Air Cooled Chiller Planned Maintenance

Water Chiller Maintenance

Process Chiller Maintenance Visit

Chilled Water System Maintenance

Air Cooled Chiller Maintenance

Centrifugal Chiller Maintenance

Industrial Chiller Maintenance

Read more about remote monitoring and control on Wikipedia | Click Here


Air cooled chiller planned maintenance showing both economizers with solenoid valves and expansion valves

Air Cooled Chiller Planned Maintenance

An air cooled chiller planned maintenance visit for a long standing customer of ours. They have just signed up to another 3 year contract. We know at Maximus Chillers that if we want to keep our customers, we must continue to offer the Maximus Service. Maximus is Latin for the highest and the greatest.

Planned Maintenance for Air Cooled Chillers

Planned maintenance is essential for these air cooled chillers as they are critical plant. They feed a large conference room which is a major part of the end user’s business. They can’t afford to loose the conference room when there is an event on. There is redundancy in the plant, but the customer always makes sure that the issues highlighted on the planned maintenance are acted on promptly. Also, the chillers feed a water cooled condenser for a pack which cools £50,000 of products used during the conferences.

Air Cooled Chiller Oil Planned Maintenance

1mw of cooling across 2 air cooled chillers were undergoing planned maintenance. Our engineer noticed that the oil level was slightly below the sight glass on one of the 250kw Bitzer compressors. The machine had previously been extensively run tested to ensure no oil return issues were present. Therefore, he decided to adjust the level with the oil available onsite.

0161 370 7193

service@maximuschillers.com

Contact Form

Economiser

The economisers, in the picture, were tested to ensure the solenoids were opening when the program sent the run signal. The electronic expansion valves functioned correctly and subcooled the liquid further after the condenser.

Head Pressure Control

The head pressure control was functioning correctly, keeping a steady 8 bar of pressure across all stages of loading and water system temperatures. This is because these chillers use a fan speed controller for each system. The fans cut in at the minimum running speed, which prevents stalling and over heating. Also, all fans running together are more reliable. Fans fail on systems using relays or pressure switches as the higher pressure fans don’t often come on. When they do, moisture has ingressed into them causing them to fail.

To read more about air cooled chiller maintenance click the Tag at the top of the page.

Related Blogs:
R134a Chilling Plant Maintenance

Water Chiller Maintenance

Process Chiller Maintenance Visit

Chilled Water System Maintenance

Air Cooled Chiller Maintenance

Centrifugal Chiller Maintenance

Industrial Chiller Maintenance