System Testing for Chiller Compressors Chiller compressors fail often as a result of ineffective servicing and system testing. At Maximus Chillers, we carry out extensive tests during our visits to ensure that small problems are resolved before they become big...
Chillers Maintenance News
Chiller Service Company
Electrical Testing A chiller service company can carry out electrical testing and diagnosis even when a wiring diagram is not available- our engineers can trace the wiring around a chiller. News Article No.3 Doing this often aids with the diagnosis even when there is...
Planned Preventative Chiller Maintenance
Featuring planned preventative chiller maintenance, which is part of a series of longer, in depth articles. News Article No.2 This time concentrating on the checks, adjustments and diagnosis our engineer carries out while on site. We can extend the life of your plant...
Chiller Maintenance Checklist
Introducing a series of in depth news articles, this time featuring the chiller maintenance checklist: News Article No.1 This article has been written with you- the customer in mind. Read below for practical advice on how to keep your chillers in the best condition....
Chiller Parts Supplier
Chiller Parts Supplier of Compressors Centrifugal As a chiller parts supplier, all kinds of centrifugal compressors are remanufactured in our workshop. With an overhead gantry crane and specialist equipment to hand- Maximus Chillers completes the picture. We have a...
Packaged Chiller Service
Packaged chiller service due to a refrigerant leak, resulting in a trip out. This visit was to identify the leak and get the plant back online. Leak Testing during Packaged Chiller Service Nitrogen was added to the system to aid in the identification of the leak. All...
Chilling Plant Maintenance Visit
On this chilling plant maintenance visit, particular attention was made to compressor loading. This was to ensure that the compressors are capable of operating at 100%. With summer now here- we want the plant capable of running at full capacity. Controller Loading...
Air Cooled Chiller Condenser Maintenance
The photo is showing air cooled chiller condenser maintenance being carried out by Maximus Chillers. 6 water cooled chillers are located in the plant room below. They are 750 kw single screw compressors with a control panel located to the side of each. On this visit,...
Process Chiller Vacuum Service
During a recent process chiller vacuum service, our engineer achieved a deep vacuum of 2 Torr. This is the same pressure as if the Torr gauge had been fitted directly to the vacuum pump. Torr Gauge The Torr gauge was fitted to a refrigerant hose. The refrigerant...
Chilling Plant Controls Maintenance
Prior to this chilling plant controls maintenance visit, another contractor had changed some of the settings and adjustments in the controllers. They did this while they were diagnosing a fault with the water system and the pumps. Therefore, this visit was to...